Confirmed against Sungrow's own docs and live-tested against a real battery plant: SOC and charge/discharge power live at the *device* level (getDeviceRealTimeData against the hybrid inverter's ps_key, device_type 14), not in the plant-aggregate points used elsewhere in this client -- querying them via the plant-level endpoint just returns null. Battery status is fetched once per live "today" poll (not backfilled historically) and stored in three new nullable columns, self-migrated on startup since there's no Alembic here. Also fixes the dashboard's self-consumption line to derive from load - import rather than generation - export, which overstated "solar -> house" for battery systems (a chunk of that gap was going into charging, not the house). The live flow diagram now shows a Battery node (SOC + charge/discharge) that stays hidden entirely for solar-only plants like Kallangur. Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com> |
||
|---|---|---|
| .. | ||